This method reads the configuration settings from a neoVI FIRE 2 device.
int _stdcall icsneoGetFIRE2Settings(void* hObject, SFIRE2Settings *pSettings,
Public Declare Function icsneoGetFIRE2Settings Lib “icsneo40.dll” (ByVal hObject As IntPtr, ByRef pSettings As SFIRE2Settings , ByVal iNumBytes As Int32) As Int32
[DllImport(“icsneo40.dll”)]publicstatic
Parameters
hObject
[in] Specifies the driver object created by OpenNeoDevice.
pSettings
[out] Pointer to a structure.
iNumBytes
[in] This value is always the size, in bytes, of the structure.
Return Values
Returns 1 if successful, 0 if an error occurred. must be called to obtain the specific error. The errors that can be generated by this function are:
NEOVI_ERROR_DLL_NEOVI_NO_RESPONSE = 75
Remarks
After getting the current settings, you may change the parameters defined in the structure and write the settings back to the neoVI FIRE 2 using .
//Declared at form level and previously open with a call to OpenNeoDeviceIntPtrm_hObject;//handle for device,SFIRE2SettingsFire2ReadSettings=newSFIRE2Settings();intiNumberOfBytes;intiResult;//Get the settingsiNumberOfBytes=System.Runtime.InteropServices.Marshal.SizeOf(Fire2ReadSettings);iResult=icsNeoDll.icsneoGetFIRE2Settings(m_hObject,refFire2ReadSettings,iNumberOfBytes);if(iResult==0){MessageBox.Show("Problem reading configuration");return;}
Private m_hObject As IntPtr '// Declared at form level and previously open with a call to OpenNeoDevice
Dim Fire2ReadSettings As SFIRE2Settings
Dim iNumberOfBytes As Integer
Dim iResult As Integer
'//Get the settings
iNumberOfBytes = System.Runtime.InteropServices.Marshal.SizeOf(Fire2ReadSettings)
iResult = icsneoGetFIRE2Settings(m_hObject, Fire2ReadSettings , iNumberOfBytes)
If iResult = 0 Then
MsgBox("Problem reading configuration")
Exit Sub
End If