ScriptReadAppSignal Method - neoVI API

This method is used to read an application signal from a script running on a neoVI device.

int _stdcall icsneoScriptReadAppSignal(void * hObject, unsigned int iIndex, double *dValue);
Public Declare Function icsneoScriptReadAppSignal Lib “icsneo40.dll” (ByVal hObject As IntPtr, ByVal iIndex As UInt32, ByRef dValue As Double) As Int32
[DllImport(“icsneo40.dll”)] public static extern Int32 icsneoScriptReadAppSignal(IntPtr hObject, UInt32 iIndex, ref double dValue);

Parameters

hObject

[in] Specifies the driver object created by OpenNeoDevice.

unsigned int iIndex

[in] The index value of the transmit message to read

double *dValue

[in] Contains the current value of the application signal.

Return Values

1 if the function succeeded. 0 if it failed for any reason. must be called to obtain the specific error. The errors that can be generated by this function are:

NEOVI_ERROR_DLL_NEOVI_NO_RESPONSE = 75

NEOVI_ERROR_DLL_SCRIPT_INVALID_APPSIG_INDEX = 225

NEOVI_ERROR_DLL_SCRIPT_NO_SCRIPT_RUNNING = 226

Remarks

The script containing the specified application signal must have been successfully downloaded to the neoVI using . The script must also have been started using . This function will fail if has been called. The valid index values for application signals within a script can be found in the cmvspy.vs3cmb.h file that is produced by Vehicle Spy. Please see Vehicle Spy documentation.

Examples

GetLastAPIError
ScriptLoadScript
ScriptStart
ScriptStop
int iRetVal;
unsigned long lLastErrNum;
double dValue = 0;

iRetVal = icsneoScriptReadAppSignal(hObject, App_Signal_1, &dValue);
if(iRetVal == 0)
{
    printf("\nFailed to read the application signal.);
}
else
{
    printf("\nApplication signal = %f\r\n", dValue);
}
Int32 iResult;
Double ValueToSet=0;

//Read App signal
iResult = icsNeoDll.icsneoScriptReadAppSignal(m_hObject, Convert.ToUInt32(cboAppSig.SelectedIndex),ref ValueToSet);

if (iResult == 0)
{
    txtAppSigVal.Text = "Problem!";
}
else
{
    txtAppSigVal.Text = Convert.ToString(ValueToSet);
}
Dim iResult As Int32
Dim ValueToSet As Double

'//Read App signal
iResult = icsneoScriptReadAppSignal(m_hObject, Convert.ToUInt32(cboAppSig.SelectedIndex), ValueToSet)

If iResult = 0 Then
    txtAppSigVal.Text = "Problem!"
Else
    txtAppSigVal.Text = Convert.ToString(ValueToSet)
End If