Sets device and network parameters for a RAD Galaxy device
GetRADGalaxySettings Method - neoVI API
This method reads the configuration settings from a RAD Galaxy device.
int _stdcall icsneoGetRADGalaxySettings(void * hObject, SRADGalaxySettings *pSettings, int iNumBytes);
Public Declare Function icsneoGetRADGalaxySettings Lib “icsneo40.dll” (ByVal hObject As IntPtr, ByRef pSettings As SRADGalaxySettings, ByVal iNumBytes As Int32) As Int32
[in] This value is always the size, in bytes, of the SRADGalaxySettings structure.
Return Values
Returns 1 if successful, 0 if an error occurred. GetLastAPIError must be called to obtain the specific error. The errors that can be generated by this function are:
NEOVI_ERROR_DLL_NEOVI_NO_RESPONSE = 75
Remarks
After getting the current settings, you may change the parameters defined in the SRADGalaxySettings structure and write the settings back to the RAD Galaxy using SetRADGalaxySettings.
Examples
SRADGalaxySettings RadGalaxyReadSettings;
int iNumberOfBytes;
int iResult;
//Get the settings
iNumberOfBytes=sizeof(RadGalaxyReadSettings );
iResult = icsneoGetRADGalaxySettings(m_hObject, &RadGalaxyReadSettings , iNumberOfBytes);
if(iResult == 0)
{
MessageBox::Show("Problem reading configuration");
return;
}
//Declared at form level and previously open with a call to OpenNeoDevice
IntPtr m_hObject; //handle for device,
SRADGalaxySettings RadGalaxyReadSettings = new SRADGalaxySettings();
int iNumberOfBytes;
int iResult;
//Get the settings
iNumberOfBytes = System.Runtime.InteropServices.Marshal.SizeOf(RadGalaxyReadSettings);
iResult = icsNeoDll.icsneoGetRADGalaxySettings(m_hObject,ref RadGalaxyReadSettings , iNumberOfBytes);
if (iResult == 0)
{
MessageBox.Show("Problem reading configuration");
return;
}
Private m_hObject As IntPtr '// Declared at form level and previously open with a call to OpenNeoDevice
Dim RadGalaxyReadSettings As SRADGalaxySettings
Dim iNumberOfBytes As Integer
Dim iResult As Integer
'//Get the settings
iNumberOfBytes = System.Runtime.InteropServices.Marshal.SizeOf(RadGalaxyReadSettings)
iResult = icsneoGetRADGalaxySettings(m_hObject, RadGalaxyReadSettings , iNumberOfBytes)
If iResult = 0 Then
MsgBox("Problem reading configuration")
Exit Sub
End If
SetRADGalaxySettings Method - neoVI API
This method reads the configuration settings from a RAD Galaxy device.
int _stdcall icsneoSetRADGalaxySettings(void * hObject, SRADGalaxySettings *pSettings, int iNumBytes, int bSaveToEEPROM);
Public Declare Function icsneoSetRADGalaxySettings Lib “icsneo40.dll” (ByVal hObject As IntPtr, ByRef pSettings As SRADGalaxySettings, ByVal iNumBytes As Int32, ByVal bSaveToEEPROM As Int32) As Int32
[in] This value is always the size, in bytes, of the SRADGalaxySettings structure.
bSaveToEEPROM
[in] If set to 0, the settings changes will revert to the values stored in EEPROM when the ValueCAN3 is power-cycled. If set to 1, the values will overwrite the EEPROM settings and become persistent across power-cycles of the ValueCAN3.
Return Values
Returns 1 if successful, 0 if an error occurred. GetLastAPIError must be called to obtain the specific error. The errors that can be generated by this function are:
SRADGalaxySettings RADGalaxyReadSettings = new RADGalaxyReadSettings();
int iNumberOfBytes;
int iResult;
iNumberOfBytes = System.Runtime.InteropServices.Marshal.SizeOf(RADGalaxyReadSettings);
iResult = icsNeoDll.icsneoSetRADGalaxySettings(m_hObject, ref RADGalaxyReadSettings , iNumberOfBytes, 1);
if(iResult == 0)
{
MessageBox.Show("Problem Sending configuration");
return;
}
Dim RADGalaxyReadSettings As SRADGalaxySettings
Dim iNumberOfBytes As Integer
Dim iResult As Integer
iNumberOfBytes = System.Runtime.InteropServices.Marshal.SizeOf(RADGalaxyReadSettings)
iResult = icsneoSetRADGalaxySettings(m_hObject, RADGalaxyReadSettings , iNumberOfBytes, 1)
If iResult = 0 Then
MsgBox("Problem Sending configuration")
Exit Sub
End If