FlexRay Controllers: Configuration Tab

Remember to select the correct Network above the tab before making any changes.

Synchronization Settings

Table 1: Configuration Tab - Synchronization Settings

SettingDescription

Sync cluster data to database

On - All settings in the Cluster branch come from a FIBEX or ARMXL file loaded in Network Databases. This also disables manual data entry of all settings in the Cluster branch. Off - All cluster settings must be entered manually.

Sync ECU data to ECUs view

On - All settings in the Nodes branch come from a FIBEX or ARMXL file loaded in Network Databases. This also disables manual data entry of all settings in the Nodes branch. An ECU is chosen for a node on the State/Action tab status table, Node Name pulldown list after loading a database. Off - All node settings must be entered manually.

Add/Remove a Channel

Toggles channel B on and off.

Cluster Branch

Vehicle Spy has many configurable cluster settings to change the FlexRay wakeup symbol, cycle structure, and segment structures. Each setting has a mouseover tooltip to briefly describe what it does. Complete definitions are in the FlexRay 2.1A protocol specification and E-Ray User's Manual, so they will not be detailed here. The settings can be loaded from a database using Sync cluster data to database or can be typed in manually and saved in a VS3 file.

Nodes Branch

Similar to the Cluster branch, there are many settings to change how each coldstart node in the ICS FlexRay hardware will operate. Each setting is already defined in the FlexRay 2.1A protocol specification and E-Ray User's Manual, so they will not be detailed here. The settings can be loaded from a database using Sync ECU data to ECUs view or can be typed in manually and saved in a VS3 file.

Channels Branch

This branch shows if channel A or both channels A and B are being used. Click Add/Remove a Channel to enable or disable channel B.