Intrepid ECU Flasher: Definitions
Last updated
Last updated
Copyright © 2024 | All Rights Reserved
The Transfer action is used to transmit data from an Intel HEX, S19, or VBF file. These file formats will contain multiple sectors, or contiguous blocks, of binary data. The ECU flasher can transfer sectors of data to the ECU and can also run Actions before any sector transfer happens, or it can run Actions before and/or after each sector in the associated file is run. The execution of the Transfer action follows the steps below:
Execute 'before_transfer_for_each_sector'
For each sector in the file:
keywords 'SECTOR_ADDR' and 'SECTOR_LEN' are updated for this sector
Execute 'before_sector_action'
Execute 'Request Download' job
Execute 'Multiple Transfer Data' job to transmit data
Execute 'after_sector_action'
end
The Transmit Action transmits an arbitrary message. This functions differently from calling a diagnostic job in that it will only transmit the defined message. Once the message is transmitted, execution immediately moves on to the next step.
TRANSFER | |
---|---|
TRANSMIT | |
---|---|
File
File path to the Intel HEX or S19 file.
before_transfer_for_each_sector_action
Action to be performed at the start of the transfer action. This only occurs once.
before_sector_action
Action to be performed prior to each sector request download / transfer data
after_sector_action
Action to be performed after each sector request download / transfer data
ID
The ARB ID for the Transmit Message. This value is in Hexidecimal.
Bytes
The bytes that should be transmitted. This works as described under Funtional Job => Bytes.